Title Reimplantation and Repeat Infection After Cardiac-Implantable Electronic Device Infections: Experience From the MEDIC (Multicenter Electrophysiologic Device Infection Cohort) Database.
Author Boyle, Thomas A; Uslan, Daniel Z; Prutkin, Jordan M; Greenspon, Arnold J; Baddour, Larry M; Danik, Stephan B; Tolosana, Jose M; Le, Katherine; Miro, Jose M; Peacock, James; Sohail, Muhammad R; Vikram, Holenarasipur R; Carrillo, Roger G
Journal Circ Arrhythm Electrophysiol Publication Year/Month 2017-Mar
PMID 28292753 PMCID -N/A-
Affiliation + expend 1.From the Department of Surgery, Division of Cardiothoracic Surgery, University of Miami, FL (T.A.B.); Department of Medicine, Division of Infectious Diseases, David Geffen School of Medicine at University of California, Los Angeles (D.Z.U.); Department of Medicine, Division of Cardiology, University of Washington, Seattle (J.M.P.); Department of Medicine, Division of Cardiology, Cardiac Electrophysiology Laboratory, Thomas Jefferson University Hospital, Philadelphia, PA (A.J.G.); Department of Medicine, Division of Infectious Diseases, Mayo Clinic College of Medicine, Rochester, MN (L.M.B., K.L., M.R.S.); Department of Medicine, Division of Cardiology, Massachusetts General Hospital, Boston (S.B.D.); Department of Medicine, Division of Infectious Diseases, Hospital Clinic, IDIBAPS, University of Barcelona, Spain (J.M.T., J.M.M.); Department of Medicine, Division of Infectious Diseases, Wake Forest School of Medicine, Winston-Salem, NC (J.P.); and Department of Medicine, Division of Infectious Diseases, Mayo Clinic, Phoenix, AZ (H.R.V.). tab127@miami.edu rcarrillo@med.miami.edu.

BACKGROUND: Infection is a serious complication of cardiovascular-implantable electronic device implantation and necessitates removal of all hardware for optimal treatment. Strategies for reimplanting hardware after infection vary widely and have not previously been analyzed using a large, multicenter study. METHODS AND RESULTS: The MEDIC (Multicenter Electrophysiologic Device Infection Cohort) prospectively enrolled subjects with cardiovascular-implantable electronic device infections at multiple institutions in the United States and abroad between 2009 and 2012. Reimplantation strategies were evaluated overall, and every patient who relapsed within 6 months was individually examined for clinical information that could help explain the negative outcome. Overall, 434 patients with cardiovascular-implantable electronic device infections were prospectively enrolled at participating centers. During the initial course of therapy, complete device removal was done in 381 patients (87.8%), and 220 of them (57.7%) were ultimately reimplanted with new devices. Overall, the median time between removal and reimplantation was 10 days, with an interquartile range of 6 to 19 days. Eleven of the 434 patients had another infection within 6 months, but only 4 of them were managed with cardiovascular-implantable electronic device removal and reimplantation during the initial infection. Thus, the repeat infection rate was low (1.8%) in those who were reimplanted. Patients who retained original hardware had a 11.3% repeat infection rate. CONCLUSIONS: Our study findings confirm that a broad range of reimplant strategies are used in clinical practice. They suggest that it is safe to reimplant cardiac devices after extraction of previously infected hardware and that the risk of a second infection is low, regardless of reimplant timing.

  • Copyright © 2023
    National Institute of Pathogen Biology, CAMS & PUMC, Bejing, China
    All rights reserved.