Title On the risk of aortic valve replacement surgery assessed by heart rate variability parameters.
Author Zebrowski, J J; Kowalik, I; Orlowska-Baranowska, E; Andrzejewska, M; Baranowski, R; Gieraltowski, J
Journal Physiol Meas Publication Year/Month 2015-Jan
PMID 25514504 PMCID -N/A-
Affiliation 1.Complex Systems Division, Faculty of Physics, Warsaw University of Technology, ul. Koszykowa 75, 00-662 Warszawa, Poland.

In recent years the number of arterial stenosis (AS) patients has grown rapidly and valvular disease is expected to be the next great epidemic. We studied a group of 385 arterial valve replacement (AVR) surgery patients, of whom 16 had died in the postoperational period (up to 30 d after the operation). Each patient had a heart rate variability (HRV) recording made prior to the operation in addition to a full set of medical diagnostics including echocardiography. We formed 16 age, sex, New York Heart Association (NYHA) class, and BMI adjusted control pairs for each person who died in the perioperative period. Our aim was to find indications of the risk from AVR surgery based on the medical data and HRV properties. Besides standard, linear HRV methods, we used indexes of time irreversibility introduced by Guzik (G%), Porta (P%), Ehlers (index E) and Hou (index D). In addition, we analyzed the multiscale multifractal properties of HRV calculating the Hurst surface. The nonlinear analysis methods show statistically significant indications of the risk of AVR surgery in an increase of multifractality and an increase of time irreversibility of the HRV measured prior to the operation.

  • Copyright © 2023
    National Institute of Pathogen Biology, CAMS & PUMC, Bejing, China
    All rights reserved.